About Turbidity Meter - TB 300 IR
Turbidity Meter
Gaining immense appreciation from clients, we are continuously supplying an excellent range of Turbidity Meter - TB 300 IR. This instrument is widely used for measuring the turbidity present in a liquid sample. Widely used in laboraotries for various research works, this turbidity meter is offered to clients in various models and specifications to meet their diverse needs. We offer this Turbidity Meter - TB 300 IR to clients after inspecting its quality on various standard parameters.
Features:
- High level of accuracy
- Rugged design
- Long term durability
Highlights
- Meets EN ISO 7027
- Autoranging
- High accuracy
- Laboratory and mobile use
- RS 232 interface
- Storage for up to 1000 data-sets
- Real-time clock
- Waterproof sample chamber and housing
Precise Nephelometric MeasurementThe TB 300 IR utilizes a nephelometric method with an infrared LED light source, as specified under ISO 7027. This ensures accurate and dependable turbidity readings from 0 to 1000 NTU, suitable for both professional laboratories and field analysis in water treatment or environmental monitoring.
Effortless Calibration and UsageCalibrating the instrument requires only distilled water for zero and a 100 NTU formazin standard, making setup straightforward and efficient. The single cell, 10 ml glass cuvette design means handling and sample preparation are simplified for routine turbidity testing.
Robust Design and Reliable ResultsEncased in an ABS plastic body, the TB 300 IR is built to withstand demanding environments. Its digital LCD display provides clear readings, while minimal power consumption and precise accuracy ensure consistent measurements regardless of location or operator skill.
FAQs of Turbidity Meter - TB 300 IR:
Q: How does the TB 300 IR Turbidity Meter operate?
A: The TB 300 IR measures turbidity using nephelometric technology, where an infrared LED emits light at 860 nm through the sample. The sensor detects the amount of light scattered by particles in the water, displaying the turbidity value in NTU on its digital LCD.
Q: What type of calibration is required for accurate measurements?
A: Calibration involves using distilled water to set the zero point (0 NTU) and a 100 NTU formazin or equivalent standard. This ensures the instrument maintains accuracy in compliance with ISO 7027 guidelines.
Q: When should I recalibrate the turbidity meter?
A: Recalibration is recommended before each measurement series, after extended use, or if there are changes in environmental conditions such as temperature and humidity. Regular calibration ensures ongoing accuracy.
Q: Where can the TB 300 IR be effectively used?
A: This meter is ideal for laboratories, water treatment facilities, environmental monitoring sites, and research settings throughout India, particularly wherever precise water clarity analysis is needed.
Q: What is the measurement process using this device?
A: Add a 10 ml water sample to the provided glass cuvette, insert it into the meter, and wait for the warm-up period. The LCD will display the turbidity level, enabling quick and efficient testing.
Q: How can users benefit from this turbidity meter?
A: With straightforward calibration, reliable performance, and ISO-compliance, users benefit from accurate turbidity measurements, a quick testing process, and durable equipment build, all of which save time and effort for routine analyses.
Q: What are the power requirements and environmental tolerances for the TB 300 IR?
A: The instrument operates on 230 V AC (10%), 50 Hz power supply, and is designed to function effectively within 5C to 40C temperatures and up to 80% relative humidity, making it suitable for diverse lab conditions.